other
  • What Are The Features Of Water Cooled Screw Chillers? Dec 05, 2025
    The water cooled screw chiller is a crucial piece of equipment in industries with strict cooling requirements, such as industrial production and commercial buildings. It combines advanced refrigeration technology with efficient heat exchange systems, offering a range of unique advantages. Hengde's water cooled screw chiller has become a benchmark for quality in the industry.   1. Efficient and Stable Compressor Performance Hengde’s water-cooled screw chiller uses imported semi-hermetic twin-screw compressors, which offer significant advantages over traditional reciprocating compressors. These screw compressors provide efficient compression, quickly and steadily compressing refrigerant gas to provide powerful cooling. During operation, the compressor runs quietly, significantly reducing noise pollution in the workplace. The simple operation minimizes technical requirements and workload for operators. Additionally, the internal structure is designed for minimal wear on moving parts, ensuring a long service life and reducing maintenance and replacement costs, thus offering reliable long-term cooling performance.   2. High-Quality and Reliable Refrigeration Valves Hengde’s water-cooled screw chillers use refrigeration valves from renowned brands such as Emerson (USA), Danfoss (Denmark), and Carel (Italy). These high-quality valves are known for their excellent performance and durability. They provide precise flow control and pressure regulation, ensuring efficient and stable refrigerant circulation within the system. The accuracy of these valves not only ensures stable cooling performance but also optimizes energy usage, contributing to energy-saving, efficient operation. Additionally, the reliability of these components reduces the risk of downtime due to valve failures, ensuring continuous system operation.   3. Efficient Heat Exchange System The evaporator and condenser of Hengde’s water cooled screw chiller are equipped with the latest high-efficiency spiral heat exchange copper tubes, which have a high heat transfer coefficient. In the evaporator, these copper tubes quickly absorb heat from the cooled medium, causing the refrigerant to evaporate rapidly, achieving efficient cooling. In the condenser, they efficiently transfer heat from the refrigerant to the cooling water, speeding up the condensation process. This high-efficiency heat exchange ensures superior cooling performance, allowing Hengde’s water cooled screw chiller to handle larger heat loads within a shorter time, making it suitable for various scale refrigeration requirements.   4. Advanced and Intelligent Control System Hengde’s water cooled screw chiller adopts an imported microcomputer control system, with an optional Siemens PLC control system. The advanced control system continuously monitors critical parameters such as temperature, pressure, and flow rate, adjusting the operation mode based on real-time needs. By using precise control algorithms, the system can coordinate the operation of compressors, water pumps, cooling towers, and other components, ensuring the chiller operates at peak performance. An optional RS485 communication function allows the unit to be integrated into an automation management system for remote monitoring, fault alarms, and data analysis, improving operational efficiency and convenience.   5. Independent and Convenient Refrigeration Circuits The water cooled screw chiller features independent refrigeration circuits, meaning each circuit can be maintained and serviced separately without affecting the overall operation. If one circuit fails, the other circuits will continue to function, ensuring uninterrupted cooling. This design greatly enhances the maintainability and flexibility of the equipment, reduces maintenance costs and downtime, and minimizes the impact on production.   6. Comprehensive Safety Protections and Energy-Efficient Operation The chiller is equipped with multiple safety protection features, including thermal protection, power protection, water flow protection, antifreeze protection, high-pressure protection, low-pressure protection, overload protection, phase loss protection, and voltage protection. All fault alerts are displayed in both English and Chinese on the operation screen for easy identification and troubleshooting. These protections prevent damage to the chiller in harsh operating conditions, ensuring safe operation and extending the unit’s lifespan. Additionally, through intelligent control and optimized design, the chiller operates at maximum efficiency with minimal energy consumption, providing a reliable and energy-saving solution that helps users reduce operational costs.   7. High-Quality Electrical Components and Protective Design The chiller uses high-quality electrical components from international brands such as Siemens, Schneider, and LS, which are known for their stability and reliability. The control panel is rated at IPX22 for protection against dust and water droplets, and higher protection ratings are available to suit more demanding environments. This protective design ensures that the chiller operates safely and reliably in complex working conditions, safeguarding the internal electrical components from potential damage.   The water cooled screw chiller, with its efficient cooling performance, stable operation, easy maintenance, and advanced control technology, is an ideal choice for industrial and commercial refrigeration needs. Hengde’s water cooled screw chiller excels in key components selection, system design, and safety features, providing users with high-quality, reliable, and energy-efficient cooling solutions. Its reputation for quality and performance has earned it widespread recognition in the market.   Choose Hengde, Choose Perfect Industrial Chillers!
  • Installation Guide for Screw Type Industrial Chillers Mar 19, 2026
    Screw-type industrial chillers play a crucial role in industrial production by providing stable cooling support for various processes. Proper installation is the foundation for ensuring efficient and stable operation. With extensive expertise in the refrigeration industry, Hengde provides a comprehensive and detailed guide for installing screw-type industrial chillers.   1. Choosing the Right Environment Select a dry, well-ventilated, and level installation site. Hengde recommends keeping the site away from heat sources, water sources, and flammable or explosive materials to ensure operational safety. Additionally, allow sufficient space around the equipment for easy operation, maintenance, and inspection. Generally, a clearance of at least 1m - 1.5m should be maintained around the unit.   2. Ensuring a Stable Power Supply Verify that the onsite power supply meets the chiller's requirements, including voltage, frequency, and phase configuration. The screw-type chiller operates on a three-phase four-wire power system: (R, S, T) for live wires (N) for neutral (G) for ground Hengde’s water cooled screw chillers and air cooled screw chillers use high-quality electrical components that are highly adaptable to power fluctuations. However, a stable and reliable power supply is still essential. Each unit is factory-equipped with comprehensive grounding protection and pre-configured settings, making it easy for users to connect according to specifications.   Additional Considerations for Industrial Screw Chiller Installation 1. Equipment Inspection & Site Selection Before installation, inspect the equipment for any damage. Choose a location that allows easy installation and maintenance. Ensure the ground is level, with a maximum unevenness of 6.4mm, and that it can support the chiller's operating weight.   2. Piping Selection & Connection Choose the appropriate pipe diameter based on the chiller’s maximum power requirements. Ensure the cooling water system and chilled water system are correctly connected.   3. Room Environment Requirements The chiller should be installed in a room with a temperature range of 4°C to 43°C. Leave adequate space around the unit for routine maintenance.   4. Pipeline Design & Installation Follow standard guidelines for installing chilled water and cooling water pipelines. Install the chilled water pump on the inlet pipe to maintain stable pressure and flow inside the unit. Use vibration dampers in the piping system to prevent water hammer effects in the evaporator when the system stops.   Final Commissioning After Installation 1. Equipment Inspection Before starting the chiller, conduct a comprehensive inspection to verify. Correct pipeline and electrical connections. Proper installation of all components.   2. Pre-Startup Preparation Add an appropriate amount of lubricant to the compressor. Check the refrigerant charge to ensure it meets the system’s requirements. Start the cooling water pump and chilled water pump to establish a normal water circulation system.   3. Equipment Commissioning Follow Hengde’s operation manual to start the chiller step by step. Closely monitor key parameters such as: Compressor sound and vibration Current draw Operating stability Adjust the operating parameters based on actual working conditions to achieve optimal cooling performance.   Hengde's Comprehensive Support Throughout the installation process of screw-type industrial chillers, Hengde provides full-scale technical support, including:  * Site planning & construction guidance * On-site technical support during installation * Commissioning and after-sales maintenance services   Hengde’s dedicated technical team works closely with customers to ensure smooth installation, delivering reliable cooling solutions for industrial production.

Need Help? Chat with us

leave a message
For any request of information or technical support, fill in the form. All fields marked with an asterisk (*) are required.
Submit

Home

Products

whatsApp

contact