other
  • Installation Guide for Screw Type Industrial Chillers Mar 19, 2026
    Screw-type industrial chillers play a crucial role in industrial production by providing stable cooling support for various processes. Proper installation is the foundation for ensuring efficient and stable operation. With extensive expertise in the refrigeration industry, Hengde provides a comprehensive and detailed guide for installing screw-type industrial chillers.   1. Choosing the Right Environment Select a dry, well-ventilated, and level installation site. Hengde recommends keeping the site away from heat sources, water sources, and flammable or explosive materials to ensure operational safety. Additionally, allow sufficient space around the equipment for easy operation, maintenance, and inspection. Generally, a clearance of at least 1m - 1.5m should be maintained around the unit.   2. Ensuring a Stable Power Supply Verify that the onsite power supply meets the chiller's requirements, including voltage, frequency, and phase configuration. The screw-type chiller operates on a three-phase four-wire power system: (R, S, T) for live wires (N) for neutral (G) for ground Hengde’s water cooled screw chillers and air cooled screw chillers use high-quality electrical components that are highly adaptable to power fluctuations. However, a stable and reliable power supply is still essential. Each unit is factory-equipped with comprehensive grounding protection and pre-configured settings, making it easy for users to connect according to specifications.   Additional Considerations for Industrial Screw Chiller Installation 1. Equipment Inspection & Site Selection Before installation, inspect the equipment for any damage. Choose a location that allows easy installation and maintenance. Ensure the ground is level, with a maximum unevenness of 6.4mm, and that it can support the chiller's operating weight.   2. Piping Selection & Connection Choose the appropriate pipe diameter based on the chiller’s maximum power requirements. Ensure the cooling water system and chilled water system are correctly connected.   3. Room Environment Requirements The chiller should be installed in a room with a temperature range of 4°C to 43°C. Leave adequate space around the unit for routine maintenance.   4. Pipeline Design & Installation Follow standard guidelines for installing chilled water and cooling water pipelines. Install the chilled water pump on the inlet pipe to maintain stable pressure and flow inside the unit. Use vibration dampers in the piping system to prevent water hammer effects in the evaporator when the system stops.   Final Commissioning After Installation 1. Equipment Inspection Before starting the chiller, conduct a comprehensive inspection to verify. Correct pipeline and electrical connections. Proper installation of all components.   2. Pre-Startup Preparation Add an appropriate amount of lubricant to the compressor. Check the refrigerant charge to ensure it meets the system’s requirements. Start the cooling water pump and chilled water pump to establish a normal water circulation system.   3. Equipment Commissioning Follow Hengde’s operation manual to start the chiller step by step. Closely monitor key parameters such as: Compressor sound and vibration Current draw Operating stability Adjust the operating parameters based on actual working conditions to achieve optimal cooling performance.   Hengde's Comprehensive Support Throughout the installation process of screw-type industrial chillers, Hengde provides full-scale technical support, including:  * Site planning & construction guidance * On-site technical support during installation * Commissioning and after-sales maintenance services   Hengde’s dedicated technical team works closely with customers to ensure smooth installation, delivering reliable cooling solutions for industrial production.

Need Help? Chat with us

leave a message
For any request of information or technical support, fill in the form. All fields marked with an asterisk (*) are required.
Submit

Home

Products

whatsApp

contact